6 inches 15 cm for appliances up to 10 000 btu hr 3 kw 12 inches 30 cm for appliances between 10 000 btu hr 3 kw and 100 000 btu hr 30 kw 36 inches 91 cm for appliances above 100 000 btu hr 30 kw 3.
Direct vent gas fireplace clearance to windows.
Empire tahoe deluxe 36 direct vent ng millivolt fireplace.
The fire clearances for a gas heater that s what we re discussing right that s direct vented can vary depending on the flue vent connector or vent material and type from 0 to perhaps 6 tell me the brand and model of your heater and we ll take a look too.
4 4 out of 5 stars 2.
The enviro heat distribution kit does not change the mantel requirements.
We marked on your gas vent photo the two measurements that are typically made.
The heat can be shifted above the unit or to another room.
Typical clearance from an operable window to a direct vented gas appliance vent outlet.
These fireplaces burn efficiently enough to be a heat source but not too efficient to where the fire lacks realism.
Available with their linear direct vent zero clearance fireplaces the enviro heat distribution kit also makes it possible to hang a tv above a fireplace.
1 16 of 235 results for direct vent gas fireplace empire comfort systems tahoe clean face direct vent mv deluxe 42 lp fireplace with blower.
The small pipe vents exhaust gases to the outdoors while the outer larger pipe pulls in oxygen for combustion.
Direct vent fireplaces use a coaxial vent system which features a small pipe within a larger pipe.
Only 3 left in stock order soon.
The outer pipe also acts as an insulator to keep the surface temperature of the vent system lower.
Q a on clearance distances needed for direct vent chimneys or exhaust for gas fireplaces gas fireplace inserts.
How a direct vent gas fireplace works.
The vertical distance to the window and the horizontal distance to the window from the nearest point of the gas vent.
Direct vent gas vent clearance required depend in part on the size in btus btuh or thousands of btus per hour input rating of the heating appliance.
Clearance distance from gas vent termination cap to any mechanical air supply inlet.
48 travis 2016 clearance to the side of any non mechanical supply air inlet.
As per b149 1 a vent shall not terminate within 12 of a door or window for appliances with inputs from 10 000 100 000 btuh so yes you are correct at 12 quick navigation fireplaces top site areas.
36 travis 2016 clearance to each side of center line extended above the gas meter regulator assembly.